Caladan CertifiedTested & Inspected30-Day WarrantyGlobal Shipping

Market Data

Coming Soon for APC InfraStruXure PDU — Used & Refurbished (APC)

Price history and market activity data is being compiled.

Place a Bid or Ask →
🖥️

APC

Photo Coming Soon

Power & Cooling

APC

APC InfraStruXure PDU — Used & Refurbished (APC)

Part No. APC InfraStruXure PDU

$200$8,000

Typical used pricing · Based on verified sales

Save 40-60% vs OEM new
Available by Request

Last verified: 2026-05-14

Tested & inspected
Documentation included
Fast worldwide shipping
30-day functional warranty
Escrow payment available

Block 1:

How Much Does APC InfraStruXure PDU Cost in 2026?

Used APC InfraStruXure PDUs in 2026 range from $200–$8,000, depending on condition and model. Used units (tested, no cosmetic repairs) start at $200–$1,200. Refurbished models (replaced capacitors, relabeled outlets) cost $2,500–$5,000. Vendor-certified (APC or third-party certified, full calibration) units hit $6,000–$8,000. Savings vs new OEM list price (typically $12,000–$18,000) average 40–70%. Caveat: Pre-2015 models lack modern SNMP monitoring ports, requiring $300–$500 adapter modules for compatibility with 2020+ data-center management systems.

Block 2:

APC InfraStruXure PDU Specifications and Compatible Systems

Key specs: 208V AC input, 30A circuit breaker, 24 NEMA L6-30R outlets (12 per phase), 1U rack form factor, SNMPv3 monitoring. Models 1S13-0001 (2012) and 1S13-0003 (2015) support 480V delta configurations. Compatible with APC NetShelter SX (2008–2016), Rittal TS 8 (2010–2018), and Liebert CRAC units pre-2019. Warning: Do not install in racks with 4-post 22U+ depth without verifying cable management arm clearance (minimum 21.5" rear depth required).

Block 3:

What to Check Before Buying a Used APC InfraStruXure PDU in 2026

  1. Voltage stability: Use a Fluke 117 multimeter to measure phase balance. Delta between L1-L2-L3 must be <3% (e.g., 208V ±6V).
  2. Outlet integrity: Test all 24 outlets with a Kill A Watt meter. Ensure each draws 23A max (15% headroom from 30A rating).
  3. Breaker trip test: Manually trip the main breaker 5x. Failure to reset indicates

Quick Info

ConditionUsed
GradeB
CategoryPower & Cooling
Lead Time1-2 weeks after sourcing
Secondary Market

Place a Bid or Ask

Connect with verified buyers and sellers for APC InfraStruXure PDU — Used & Refurbished (APC).

Want to Buy
Want to Sell

All transactions are export compliant · Escrow available · parts@caladansemi.com