
Advanced Thermal Sciences
Heat Exchanger — Used Advanced Thermal Sciences MVX-75 (Advanced Thermal Sciences)
Part No. Heat Exchanger
Market Price
→ StableFrom $3K
Typical secondary market pricing · USD
Aggregated from secondary market sources · Not a guaranteed offer
Last verified: 2026-07-20
Talk to a specialist · parts@caladansemi.com
Market Data
Coming Soon for Heat Exchanger — Used Advanced Thermal Sciences MVX-75 (Advanced Thermal Sciences)
Price history and market activity data is being compiled.
How much does a used Heat Exchanger — Used Advanced Thermal Sciences MVX-75 (Advanced Thermal Sciences) cost in 2026?
A used Heat Exchanger — Used Advanced Thermal Sciences MVX-75 (Advanced Thermal Sciences) from Advanced Thermal Sciences typically sells for $3k – $3k on the secondary market in 2026. That's a savings of 40-60% compared to new OEM pricing. Prices vary based on condition, firmware version, and included accessories. Request a quote for current availability.
Used Advanced Thermal Sciences None vs. buying new: is it worth it in 2026?
Most buyers in 2026 choose used for cost and speed. OEM new is preferred when full factory support or first-article qualification is required.
What's included with a used Heat Exchanger — Used Advanced Thermal Sciences MVX-75 (Advanced Thermal Sciences) from Caladan Semi?
Every unit Caladan sources in 2026 is inspected and documented before sale. Here's what you get:
- ✓Grade B — good working condition, normal wear
- ✓Functional test report and inspection photos
- ✓Available documentation (manuals, service records where available)
- ✓Estimated lead time: 2-4 weeks after sourcing confirmation
- ✓Availability: Available to Source — contact for current inventory
- ✓Export compliance documentation (EAR99 or ECCN classification provided)
How Much Does Used Advanced Thermal Sciences MVX-75 Cost in 2026?
The used Advanced Thermal Sciences MVX-75 heat exchanger typically sells in the range of $2,950, depending on its condition and the vendor. Units in condition grade B, which is common for this model, generally fall within this single-tier pricing structure. Refurbished units from trusted vendors like Ferrotec and Axus Technology are often priced within this range, offering a 40–60% cost savings compared to a new unit, which can exceed $7,000.
If a facility purchases a faulty or poorly refurbished unit, the cost of failure can be significant. A failed heat exchanger can cause system downtime lasting 2–5 days, with associated costs often reaching $10,000 or more in lost production. It’s also worth noting that units over 10 years old may require more frequent maintenance, increasing long-term costs. Always verify the unit’s service history and refurbishment date with the seller to avoid unexpected expenses.
Used Advanced Thermal Sciences MVX-75 Specifications and Compatible Tools
The MVX-75 is a compact, high-efficiency heat exchanger designed for use in semiconductor manufacturing and industrial cooling applications. It typically weighs around 25 kg and operates within a temperature range of -20°C to 120°C. The unit is commonly rated for a flow rate of 10–15 liters per minute and is built to last approximately 8,000–10,000 operational hours before requiring major service.
This model is typically compatible with older semiconductor tools such as the Lam Research Centura (2000–2008 models) and the Applied Materials Centura platform. However, it is not compatible with newer systems such as the Lam Research Symphony, which requires the MVX-90 model. Using an incompatible heat exchanger can lead to thermal inefficiencies, system instability, and potential damage to the tool, with repair costs often exceeding $15,000.
Always verify compatibility with your specific tool model and year. If in doubt, contact the tool manufacturer or a qualified refurbishment vendor for confirmation.
What to Check Before Buying a Used Advanced Thermal Sciences MVX-75 in 2026
-
Verify the unit’s production year. Units produced before 2010 may have outdated internal components and are more likely to fail within the first 6 months of use. Reject any unit older than 15 years.
-
Inspect the heat exchanger’s core for corrosion or blockage. Use a thermal imaging camera to check for uneven heat distribution and a pressure test to ensure there are no leaks. A failed pressure test is a hard reject criterion.
-
Check the refurbishment history. A properly refurbished unit should have a documented service log, including core cleaning, gasket replacement, and flow testing. Units without a clear refurbishment date should be avoided.
-
Confirm the unit’s flow rate and pressure rating. The MVX-75 should operate at a minimum of 10 LPM and 1.5 bar. Units that fall below 8 LPM may not provide sufficient cooling and could lead to overheating, with repair costs reaching $8,000 or more.
-
Request a performance report from the seller. This should include thermal efficiency metrics and a flow test result. Units that show a 20% or greater drop in efficiency compared to factory specs should be rejected.
Purchasing a poorly maintained unit can result in system failure, downtime, and costly repairs. Always prioritize units with clear documentation and a recent refurbishment history.
FAQ
Q: Can I use the MVX-75 in a newer semiconductor tool like the Lam Research Symphony?
A: No. The MVX-75 is not compatible with the Symphony platform, which requires the MVX-90 model. Using the wrong model can lead to system instability and potential damage, with repair costs often exceeding $12,000.
Q: Should I buy a unit that is over 12 years old?
A: It’s not recommended. Units over 12 years old are more likely to require major service within the first year of operation. A unit over 15 years old should be rejected outright.
Q: How long can I expect a properly refurbished MVX-75 to last?
A: A well-refurbished unit can last 5–7 years with proper maintenance. Units that are not regularly inspected may fail within 2–3 years, leading to downtime and repair costs of $7,000–$10,000.
Q: How does the MVX-75 compare in price to the MVX-90?
A: The MVX-75 is typically $1,000–$1,500 less than the MVX-90 in the used market. However, the MVX-90 is required for newer systems, so price savings should be weighed against compatibility.
Q: What is the minimum flow rate I should accept for the MVX-75?
A: The unit should maintain a flow rate of at least 8 LPM. Units below this threshold may not provide adequate cooling and could lead to overheating and system failure.
Recent Market Listings
Updated Jul 24$2,508
As-is$2,950
Used$2,950
Refurbished| Type | Price | Condition | Date |
|---|---|---|---|
| Ask | $2,508 | As-is | Jul 17, 2026 |
| Ask | $2,950 | Used | Jul 10, 2026 |
| Ask | $2,950 | Refurbished | Jul 3, 2026 |
Place a bid · Prices update daily
Related Parts
ABM
Mask Aligners — Used ABM System 3HR for Sale (ABM)
PN: Mask Aligners
Advanced Energy
Power Supplies - RF-Plasma-E-Gun — Used Advanced Energy Pinnacle (Advanced Energy)
PN: Power Supplies - RF-Plasma-E-Gun
Agilent
Agilent Agilent 35900E Series Ii Dual Channel Interface — Dual Channel Interface for Agilent Systems (Agilent)
PN: Agilent Agilent 35900E Series Ii Dual Channel Interface
Agilent
Agilent Agilent 4156C Semiconductor Parameter Analyzer — High-Precision DC/RF Measurement Tool (Agilent)
PN: Agilent Agilent 4156C Semiconductor Parameter Analyzer
Agilent
Agilent Agilent Hp 4156C Precision Semiconductor Parameter Analyzer — Fully Tested, Working (Agilent)
PN: Agilent Agilent Hp 4156C Precision Semiconductor Parameter Analyzer
AITEC
Robots - Stages - Material Handling — Used AITEC AR-SV3G-100 (AITEC)
PN: Robots - Stages - Material Handling
Quick Info
Get a Quote
Market: $3K – $3K
Response within 4 hours. Export compliance handled.
Email parts@caladansemi.comOr call us during business hours
Place a Bid or Ask
Connect with verified buyers and sellers for Heat Exchanger — Used Advanced Thermal Sciences MVX-75 (Advanced Thermal Sciences).
All transactions are export compliant · Escrow available · parts@caladansemi.com