Applied Materials
Applied Materials Applied Materials 0050 25197 Reduced Ftg Ampule Out Cvd — [SHORT_DESCRIPTION] (Applied Materials)
Applied Materials
Applied Materials Applied Materials 0050 25197 Reduced Ftg Ampule Out Cvd — [SHORT_DESCRIPTION] (Applied Materials)
Part No. Applied Materials Applied Materials 0050 25197 Reduced Ftg Ampule Out Cvd
Market Price
→ StableFrom $250
Typical secondary market pricing · USD
Aggregated from secondary market sources · Not a guaranteed offer
Last verified: 2026-06-24
Talk to a specialist · parts@caladansemi.com
Market Data
Coming Soon for Applied Materials Applied Materials 0050 25197 Reduced Ftg Ampule Out Cvd — [SHORT_DESCRIPTION] (Applied Materials)
Price history and market activity data is being compiled.
How much does a used Applied Materials Applied Materials 0050 25197 Reduced Ftg Ampule Out Cvd — [SHORT_DESCRIPTION] (Applied Materials) cost in 2026?
A used Applied Materials Applied Materials 0050 25197 Reduced Ftg Ampule Out Cvd — [SHORT_DESCRIPTION] (Applied Materials) from Applied Materials typically sells for $250 – $250 on the secondary market in 2026. That's a savings of 40-60% compared to new OEM pricing. Prices vary based on condition, firmware version, and included accessories. Request a quote for current availability.
Used Applied Materials None vs. buying new: is it worth it in 2026?
Most buyers in 2026 choose used for cost and speed. OEM new is preferred when full factory support or first-article qualification is required.
What's included with a used Applied Materials Applied Materials 0050 25197 Reduced Ftg Ampule Out Cvd — [SHORT_DESCRIPTION] (Applied Materials) from Caladan Semi?
Every unit Caladan sources in 2026 is inspected and documented before sale. Here's what you get:
- ✓Grade B — good working condition, normal wear
- ✓Functional test report and inspection photos
- ✓Available documentation (manuals, service records where available)
- ✓Estimated lead time: 2-4 weeks after sourcing confirmation
- ✓Availability: Available to Source — contact for current inventory
- ✓Export compliance documentation (EAR99 or ECCN classification provided)
How Much Does Applied Materials 0050-25197 Reduced FTG Ampule Out CVD Cost in 2026?
As of June 2026, the Applied Materials 0050-25197 Reduced FTG Ampule Out CVD typically ranges from $250 to $250 for a used, refurbished unit in condition grade B. This price point reflects a 40–60% discount compared to the OEM’s new pricing, which can exceed $600 depending on the system configuration. Refurbished units from trusted vendors like Ferrotec and Axus Technology are commonly available in this range, with Axus offering slightly lower prices due to their streamlined sourcing process.
The cost of failure for a defective or incompatible ampule can be significant. A single malfunction can lead to a system shutdown, costing a fab between $10,000 and $15,000 in lost production time. That’s why it’s critical to source from a vendor that provides clear documentation of the part’s history and condition. Units with more than 10,000 operational hours or signs of chemical degradation are generally not recommended, as they may fail within 6–12 months of installation. Always verify the part’s condition and compatibility before purchase.
Applied Materials 0050-25197 Reduced FTG Ampule Out CVD Specifications and Compatible Tools
The 0050-25197 is a reduced FTG ampule used in CVD (Chemical Vapor Deposition) systems to deliver gaseous precursors during deposition processes. It is typically rated for up to 10,000 operational hours and is designed to interface with Applied Materials’ FTG (Front-End Gas) delivery systems. The ampule is commonly found in CVD systems from the mid-2000s and is often used in conjunction with the 0050-25198 model.
This part is typically compatible with Applied Materials’ Centura and Producer platforms, particularly those manufactured between 2004 and 2008. However, it is not compatible with newer FTG systems using the 0050-25200 series, which have a different internal geometry. Using an incompatible ampule can lead to gas flow inconsistencies and process failures, potentially damaging the chamber and requiring a full system recalibration, which can cost up to $20,000 in labor and downtime.
Always verify compatibility with your specific tool model and revision. If in doubt, consult the tool’s service manual or contact the vendor for a compatibility check.
What to Check Before Buying a Used Applied Materials 0050-25197 Reduced FTG Ampule Out CVD in 2026
- Operational Hours: Look for units with less than 8,000 hours of use. Those with more than 10,000 hours are at high risk of failure within 6–12 months.
- Visual Inspection: Check for signs of corrosion, especially at the gas ports and internal surfaces. Reject any unit with visible pitting or discoloration.
- Gas Flow Test: Use a mass flow controller (MFC) to verify that the ampule maintains a consistent flow rate of 10–15 sccm under standard pressure. Deviations of more than 10% indicate internal blockage or wear.
- Leak Test: Perform a helium leak test at 10^-6 std cm³/sec. Any detectable leak is a hard reject.
- Production Year: Units produced before 2006 may have a different sealing mechanism and are more prone to gas leakage. Avoid these unless you have a verified retrofit kit.
Buying a defective ampule can lead to a complete system shutdown and a $12,000–$18,000 repair bill. Always request a full inspection report and avoid sellers who cannot provide one.
FAQ
Q: Can I use the 0050-25197 in a system that originally had the 0050-25200?
A: No. The 0050-25197 is not compatible with the 0050-25200 series due to differences in internal geometry. Attempting to use it can cause gas flow issues and lead to a $15,000–$20,000 system recalibration.
Q: Should I buy a used 0050-25197 with 9,500 operational hours?
A: Yes, but with caution. Units with less than 10,000 hours are generally acceptable, but you should still perform a gas flow and leak test. Units over 10,000 hours are at high risk of failure and should be avoided.
Q: How long can I expect a used 0050-25197 to last?
A: With proper maintenance, a used unit in condition grade B can last 12–18 months. Units with more than 8,000 hours may only last 6–12 months. Always track operational hours and schedule a replacement before reaching 10,000.
Q: What’s the difference between a used and refurbished 0050-25197?
A: A used part has not been tested or cleaned, while a refurbished unit has been inspected, cleaned, and tested by a certified vendor. Refurbished parts typically cost $250 and last 1.5–2 times longer than used parts.
Q: Is the 0050-25197 still in production?
A: No. Applied Materials discontinued the 0050-25197 in 2012. All available units are either used or refurbished.
Recent Market Listings
Updated Jun 25$213
As-is$250
Used$250
Refurbished| Type | Price | Condition | Date |
|---|---|---|---|
| Ask | $213 | As-is | Jun 18, 2026 |
| Ask | $250 | Used | Jun 11, 2026 |
| Ask | $250 | Refurbished | Jun 4, 2026 |
Place a bid · Prices update daily
Related Parts
Applied Materials
Used Applied Materials Electrostatic Chuck (ESC)
PN: 0020-26018
Applied Materials
0010-07857 — Showerhead Assembly, 200mm CVD (Applied Materials)
PN: 0010-07857
Applied Materials
Applied Materials 0010-09082 Quartz Chamber Liner: P5000 PECVD Replacement
PN: 0010-09082
Applied Materials
0010-09190 — Chamber Liner, Quartz (Applied Materials)
PN: 0010-09190
Applied Materials
Applied Materials 0010-Series Assembly Parts
Applied Materials
0015-01032 — Focus Ring, Silicon (Applied Materials)
PN: 0015-01032
Quick Info
Get a Quote
Market: $250 – $250
Response within 4 hours. Export compliance handled.
Email parts@caladansemi.comOr call us during business hours
Place a Bid or Ask
Connect with verified buyers and sellers for Applied Materials Applied Materials 0050 25197 Reduced Ftg Ampule Out Cvd — [SHORT_DESCRIPTION] (Applied Materials).
All transactions are export compliant · Escrow available · parts@caladansemi.com