Caladan CertifiedExport Compliant30-Day WarrantyEscrow Protected
Gas Chomatograph — Used HP G1530A/ 6890 FID and NPD Detectors (Bidservice) — Bidservice
Market listing photo
Market photo

Bidservice

Gas Chomatograph — Used HP G1530A/ 6890 FID and NPD Detectors (Bidservice)

Part No. Gas Chomatograph

Market Price

→ Stable
1 active listing

From $2K

Typical secondary market pricing · USD

Low $1,500Avg $1,500High $1,500
Save 40-60% vs OEM new

Aggregated from secondary market sources · Not a guaranteed offer

Available by Request

Last verified: 2026-07-22

Tested & inspected
Documentation included
Fast worldwide shipping
30-day functional warranty
Escrow payment available

Market Data

Coming Soon for Gas Chomatograph — Used HP G1530A/ 6890 FID and NPD Detectors (Bidservice)

Price history and market activity data is being compiled.

Place a Bid or Ask →

How much does a used Gas Chomatograph — Used HP G1530A/ 6890 FID and NPD Detectors (Bidservice) cost in 2026?

A used Gas Chomatograph — Used HP G1530A/ 6890 FID and NPD Detectors (Bidservice) from Bidservice typically sells for $2k – $2k on the secondary market in 2026. That's a savings of 40-60% compared to new OEM pricing. Prices vary based on condition, firmware version, and included accessories. Request a quote for current availability.

Used Bidservice None vs. buying new: is it worth it in 2026?

Used (2026)
Save 40-60% vs. new OEM
Lead time: 2-4 weeks
Condition: B grade
30-day functional warranty
New OEM
Full OEM price (1–2.5× used)
Lead times: 12–52 weeks
New condition, full warranty
Factory support included

Most buyers in 2026 choose used for cost and speed. OEM new is preferred when full factory support or first-article qualification is required.

What's included with a used Gas Chomatograph — Used HP G1530A/ 6890 FID and NPD Detectors (Bidservice) from Caladan Semi?

Every unit Caladan sources in 2026 is inspected and documented before sale. Here's what you get:

  • Grade B — good working condition, normal wear
  • Functional test report and inspection photos
  • Available documentation (manuals, service records where available)
  • Estimated lead time: 2-4 weeks after sourcing confirmation
  • Availability: Available to Source — contact for current inventory
  • Export compliance documentation (EAR99 or ECCN classification provided)

How Much Does Used HP G1530A/ 6890 Gas Chromatograph FID and NPD Detectors Cost in 2026?

In 2026, the used market for HP G1530A/ 6890 Gas Chromatograph FID and NPD Detectors typically ranges from $1,500 to $1,500, depending on condition and refurbishment history. Units in condition grade B, like the one available from Bidservice, are commonly priced around $1,500. For higher-grade units (A or A-), expect to pay up to $2,000, while lower-grade (C) units may be available for as low as $1,000. Refurbishers like Axus Technology and Ferrotec often handle these models, offering quality assurance and performance validation.

Compared to a new HP G1530A detector, which can cost upwards of $4,000, the used option offers savings of 40–60%. This can translate into significant cost avoidance, especially for labs with multiple instruments or those on a tight capital budget. A failed or delayed installation due to a faulty used detector could cost $1,000–$2,000 in downtime and repair costs, so it’s critical to verify condition and performance before purchase.

Condition is a key factor. Units with more than 10,000 operating hours or signs of physical wear may not perform reliably, even after refurbishment. Always request a detailed inspection report and, if possible, a bench test.


Used HP G1530A/ 6890 Gas Chromatograph FID and NPD Detectors Specifications and Compatible Tools

The HP G1530A/ 6890 Gas Chromatograph FID and NPD Detectors are designed for high-precision gas analysis in environmental, pharmaceutical, and petrochemical labs. These detectors typically support temperature ranges from 40°C to 350°C and feature a flow rate range of 0.1 to 100 mL/min. They are commonly rated for 10,000–15,000 operational hours before requiring major service.

These detectors are compatible with HP 6890 and HP 5890 series gas chromatographs, particularly models from the late 1990s to early 2000s. They are not compatible with newer Agilent 7890 or 8890 series systems due to differences in interface protocols and power requirements.

Failure to verify compatibility can lead to integration delays and costly rework. A mismatch with part number 5989-0268 or similar could result in a non-functional setup, costing $1,500–$2,500 in labor and parts to correct. Always cross-reference with the user manual or contact the vendor for confirmation.


What to Check Before Buying a Used HP G1530A/ 6890 Gas Chromatograph FID and NPD Detectors in 2026

  1. Verify Operating Hours: Look for units with less than 12,000 hours of use. Units with more than 15,000 hours are at risk of internal component failure and should be avoided.

  2. Test with a Known Sample: Request a bench test using a standard sample like n-hexane or methane. A properly functioning FID should detect the sample with a signal-to-noise ratio above 100:1.

  3. Check for Physical Damage: Inspect for cracks, corrosion, or signs of overheating. Any visible damage to the detector housing or internal components is a hard REJECT IF criterion.

  4. Confirm Refurbishment History: Ask for the date of last service and whether the unit was fully rebuilt or just cleaned. Units not serviced since 2018 or earlier may require immediate internal work.

  5. Request a Performance Report: A detailed report should include baseline stability, noise levels, and response time. Units with baseline drift over 0.1 mV/min should be flagged.

Purchasing a unit that fails to meet these criteria can lead to a $1,000–$2,000 loss in downtime and repair costs. Always insist on a 30-day return policy or performance guarantee.


FAQ

Q: Can I use this detector with an Agilent 7890 GC?
A: No. The HP G1530A/ 6890 detectors are not compatible with Agilent 7890 systems due to differences in interface and power requirements. Attempting to use them could damage both the detector and the GC, costing $1,500–$3,000 in repairs.

Q: Should I buy a used HP G1530A detector if I need it for high-throughput work?
A: Yes, but only if the unit has under 10,000 hours and was recently serviced. High-throughput environments can push older detectors to failure within 6–12 months if they’re not in top condition.

Q: How long can I expect this detector to last with regular use?
A: With proper maintenance and under 12,000 hours of use, you can expect 2–3 years of reliable performance. Beyond that, internal components like the ionization chamber and gas inlets may degrade, increasing the risk of failure.

Q: What’s the difference between FID and NPD in this model?
A: The FID (Flame Ionization Detector) is used for hydrocarbon analysis and is generally more stable. The NPD (Nitrogen Phosphorus Detector) is more sensitive to nitrogen- and phosphorus-containing compounds but is more prone to drift and requires more frequent calibration. NPDs typically last 10–15% fewer hours than FIDs under similar conditions.

Q: How much can I save by buying used instead of new?
A: You can save between 40–60%, or $1,500–$2,500, compared to a new HP G1530A detector. However, savings are only realized if the unit is in good condition and properly refurbished.

Recent Market Listings

Updated Aug 8
AskAug 1, 2026

$1,275

As-is
AskJul 25, 2026

$1,500

Used
AskJul 18, 2026

$1,500

Refurbished

Place a bid · Prices update daily

Related Parts

Quick Info

ConditionUsed
GradeB
CategoryNone
Lead Time2-4 weeks after sourcing

Get a Quote

Market: $2K – $2K

Response within 4 hours. Export compliance handled.

Email parts@caladansemi.com

Or call us during business hours

Secondary Market

Place a Bid or Ask

Connect with verified buyers and sellers for Gas Chomatograph — Used HP G1530A/ 6890 FID and NPD Detectors (Bidservice).

Want to Buy
Want to Sell

All transactions are export compliant · Escrow available · parts@caladansemi.com