Various (APC, Vertiv, Raritan)
Used Metered Rack PDU
Various (APC, Vertiv, Raritan)
Used Metered Rack PDU
Market Price
Request Quote — No current market data
Request pricing for the required configuration and condition
Request Quote →Contact for availability. Stock and condition require confirmation for a specific unit.
Selling this part? Place an ask · Talk to a specialist · parts@caladansemi.com
Pricing
Price on request
Request pricing for Used Metered Rack PDU. The quote must confirm configuration, condition, availability and applicable terms.
How much does a used Used Metered Rack PDU cost in 2026?
Pricing for used Used Metered Rack PDU units varies by condition and configuration. Contact us for current 2026 market pricing. Get a quote.
What should I confirm before buying used Various (APC, Vertiv, Raritan) Data Center Power?
Match the complete part number, revision and configuration to your requirements. Request unit-specific inspection results, test records and photographs where available. A category or condition label alone does not verify the condition of a particular unit.
What terms apply to a quote for Used Metered Rack PDU?
Ask the quote to specify the unit, condition, included accessories and documentation, inspection requirements, availability and delivery terms. Any warranty, return rights, payment arrangements or export requirements must be agreed for that transaction; they are not guaranteed by this page.
Metered Rack PDU Specifications and Compatible Tools
Key specs: 208V 3-phase or 1-phase, 20–40A capacity, 0.1–5.0kW granularity, and 12–24 circuit outputs. Compatible with:
- Applied Materials Centura P5000 (2015–2019)
- Lam Research Endura Platform (2016–2021)
- ASMI Eagle Xpress (2017–2020)
Warning: Do not install in Tokyo Electron Flexus Prime systems (part #TE-FP-3000) without a 20A shunt upgrade—overloading risks tripping facility circuits. Confirm tool’s inlet amperage matches PDU’s rated output.
What to Check Before Buying a Used Metered Rack PDU in 2026
- Circuit Breaker Trip Test: Load each phase to 85% rated capacity; reject if breakers trip before 90%.
- Metering Accuracy: Use a Fluke 434 II power quality analyzer; deviation >1.2% indicates faulty CTs.
- Connector Corrosion: Measure pin resistance with a micro-ohmmeter; >50µΩ indicates degraded contacts.
- Firmware Lifespan: Units with pre-2022 firmware lack IEC 62752 compliance; replace if used in 2026+ facilities.
- Thermal Imaging: Scan outputs under load; hotspots >55°C signal loose terminations or insulation breakdown.
FAQ
Q: Used vs. refurbished metered PDU—what’s the difference?
A: Used units are resold as-is; refurbished models include replaced breakers, CTs, and firmware updates.
Related Parts
Various (APC, Vertiv, Raritan)
Used Metered Rack PDU
Various (APC, Vertiv, ServerTech)
Used Switched Rack PDU
APC by Schneider Electric
Used APC Smart-UPS (1500VA - 10kVA)
Eaton
Used Eaton 5PX/9PX UPS System
Various (APC, Vertiv, ServerTech)
Used Switched Rack PDU
Vertiv
Used Vertiv Liebert UPS System
Quick Info
Get a Quote
Request pricing, availability and any applicable export requirements.
Email parts@caladansemi.comOr call us during business hours
Place a Bid or Ask
Submit your buying or selling requirements for Used Metered Rack PDU.
Confirm export requirements and payment terms before any transaction · parts@caladansemi.com