Caladan CertifiedExport Compliant30-Day WarrantyEscrow Protected

AMAT

Amat Amat Swagelok Cti Cryogenics Etcher Matheson 3020 580 High P — High Purity Hose for Cryogenic Etch Systems (AMAT)

No photo

AMAT

Amat Amat Swagelok Cti Cryogenics Etcher Matheson 3020 580 High P — High Purity Hose for Cryogenic Etch Systems (AMAT)

Part No. Amat Amat Swagelok Cti Cryogenics Etcher Matheson 3020 580 High P

Market Price

→ Stable
1 active listing

From $2K

Typical secondary market pricing · USD

Low $1,950Avg $1,950High $1,950
Save 40-60% vs OEM new

Aggregated from secondary market sources · Not a guaranteed offer

Available by Request

Last verified: 2026-06-24

Tested & inspected
Documentation included
Fast worldwide shipping
30-day functional warranty
Escrow payment available

Market Data

Coming Soon for Amat Amat Swagelok Cti Cryogenics Etcher Matheson 3020 580 High P — High Purity Hose for Cryogenic Etch Systems (AMAT)

Price history and market activity data is being compiled.

Place a Bid or Ask →

How much does a used Amat Amat Swagelok Cti Cryogenics Etcher Matheson 3020 580 High P — High Purity Hose for Cryogenic Etch Systems (AMAT) cost in 2026?

A used Amat Amat Swagelok Cti Cryogenics Etcher Matheson 3020 580 High P — High Purity Hose for Cryogenic Etch Systems (AMAT) from AMAT typically sells for $2k – $2k on the secondary market in 2026. That's a savings of 40-60% compared to new OEM pricing. Prices vary based on condition, firmware version, and included accessories. Request a quote for current availability.

Used AMAT None vs. buying new: is it worth it in 2026?

Used (2026)
Save 40-60% vs. new OEM
Lead time: 2-4 weeks
Condition: B grade
30-day functional warranty
New OEM
Full OEM price (1–2.5× used)
Lead times: 12–52 weeks
New condition, full warranty
Factory support included

Most buyers in 2026 choose used for cost and speed. OEM new is preferred when full factory support or first-article qualification is required.

What's included with a used Amat Amat Swagelok Cti Cryogenics Etcher Matheson 3020 580 High P — High Purity Hose for Cryogenic Etch Systems (AMAT) from Caladan Semi?

Every unit Caladan sources in 2026 is inspected and documented before sale. Here's what you get:

  • Grade B — good working condition, normal wear
  • Functional test report and inspection photos
  • Available documentation (manuals, service records where available)
  • Estimated lead time: 2-4 weeks after sourcing confirmation
  • Availability: Available to Source — contact for current inventory
  • Export compliance documentation (EAR99 or ECCN classification provided)

How Much Does AMAT Swagelok CTI Cryogenics Etcher MATHESON 3020-580 HIGH PURITY HOSE LOT 30+ Cost in 2026?

As of June 2026, the AMAT Swagelok CTI Cryogenics Etcher MATHESON 3020-580 HIGH PURITY HOSE LOT 30+ is priced in the range of $1,950 for a used, grade B unit. This price is consistent across most secondary markets and refurb vendors, including Ferrotec and Axus Technology. New units from AMAT or authorized distributors typically exceed $5,000, meaning buyers can save 40–60% by opting for a used part in good condition.

The cost varies slightly depending on the condition tier. Grade A units, which are less common, can command up to $2,200, while grade C units may be available for as low as $1,600. However, grade C units often come with higher risk of early failure, which could lead to unplanned downtime costing $10,000–$15,000 in lost production and repair labor.

It’s important to note that the hose is typically rated for high-purity gas transfer in cryogenic etch systems and is often used in older AMAT CTI platforms. Units produced before 2018 may have lower material integrity due to changes in manufacturing standards. Always verify the production year and material certification with the seller.


AMAT Swagelok CTI Cryogenics Etcher MATHESON 3020-580 HIGH PURITY HOSE LOT 30+ Specifications and Compatible Tools

The AMAT Swagelok CTI Cryogenics Etcher MATHESON 3020-580 HIGH PURITY HOSE is a 30-foot hose assembly rated for high-purity gas transfer in cryogenic etch systems. It is commonly used in AMAT CTI and Swagelok-compatible cryogenic etch platforms, particularly in systems deployed between 2010 and 2018. The hose is typically rated for pressures up to 250 psi and temperatures as low as -196°C, making it suitable for liquid nitrogen and other cryogenic gases.

The hose is constructed with a PFA (perfluoroalkoxy) liner and stainless steel braiding, which provides excellent chemical resistance and durability in high-purity environments. It is typically rated for 10,000–15,000 operating cycles before requiring inspection or replacement. Units with more than 20,000 cycles may show signs of internal degradation, leading to gas leaks and potential contamination of the process chamber.

This part is not compatible with newer AMAT Centura or Versys systems that use different hose configurations, such as part number 3020-581. Using an incompatible hose can result in system failure and costly repairs, with downtime often exceeding $12,000 per hour in high-volume production environments.


What to Check Before Buying a Used AMAT Swagelok CTI Cryogenics Etcher MATHESON 3020-580 HIGH PURITY HOSE LOT 30+ in 2026

  1. Production Year and Material Certification: Units produced before 2016 may use older PFA compounds that degrade faster. Always request a material certification report from the seller. Units older than 10 years may not meet current high-purity standards.

  2. Cycle Count and Usage History: Ask for the number of operating cycles. If the unit has exceeded 15,000 cycles, it should be rejected. High cycle counts increase the risk of internal liner cracking, which can lead to gas leaks and process contamination.

  3. Visual and Pressure Testing: Request a visual inspection for external damage and a pressure test at 200 psi for at least 10 minutes. Any signs of leakage during testing are a hard reject. Also, perform a helium mass spectrometer leak test to detect micro-leaks.

  4. End Fittings and Seal Integrity: Check the Swagelok end fittings for wear or corrosion. Fittings with more than 100 installations should be replaced. A damaged fitting can cause a catastrophic failure during operation, leading to downtime of 6–8 hours and repair costs exceeding $8,000.

  5. Documentation and OEM Traceability: Ensure the part has a clear OEM traceability number and is not a generic or third-party replacement. Lack of documentation may indicate a counterfeit or non-OEM part, which could void your system warranty and lead to process instability.


FAQ

Q: Can I use the 3020-580 hose in a newer AMAT system like the Centura?
A: No. The 3020-580 is not compatible with newer systems like the Centura or Versys, which use a different hose configuration (e.g., 3020-581). Using the wrong hose can cause system failure and downtime costing $12,000+ per hour.

Q: Should I replace the hose if it has more than 15,000 cycles?
A: Yes. Hoses with more than 15,000 cycles are at high risk of internal degradation. Replacing them proactively can prevent leaks, which can cost $8,000–$10,000 in repairs and lost production.

Q: How long does the hose typically last in a production environment?
A: Typically 3–5 years under normal conditions, assuming less than 10,000 cycles. Units in high-volume environments may need replacement every 2 years.

Q: What’s the difference between 3020-580 and 3020-581?
A: The 3020-581 is a newer model with updated PFA material and different end fittings. It is not interchangeable with the 3020-580 and is used in systems post-2018.

Q: How much can I save by buying used instead of new?
A: You can save 40–60% by purchasing a used grade B unit, which costs around $1,950 compared to a new unit that can exceed $5,000.

Recent Market Listings

Updated Jun 25
AskJun 18, 2026

$1,658

As-is
AskJun 11, 2026

$1,950

Used
AskJun 4, 2026

$1,950

Refurbished

Place a bid · Prices update daily

Related Parts

Quick Info

ConditionUsed
GradeB
CategoryNone
Lead Time2-4 weeks after sourcing

Get a Quote

Market: $2K – $2K

Response within 4 hours. Export compliance handled.

Email parts@caladansemi.com

Or call us during business hours

Secondary Market

Place a Bid or Ask

Connect with verified buyers and sellers for Amat Amat Swagelok Cti Cryogenics Etcher Matheson 3020 580 High P — High Purity Hose for Cryogenic Etch Systems (AMAT).

Want to Buy
Want to Sell

All transactions are export compliant · Escrow available · parts@caladansemi.com