Confirm condition, inspection evidence and commercial terms in the quote.

KLA-Tencor

700-123456-00 — Stage Assembly, XY (KLA-Tencor)

No photo

KLA-Tencor

700-123456-00 — Stage Assembly, XY (KLA-Tencor)

Part No. 700-123456-00

Market Price

Request Quote — No current market data

Request pricing for the required configuration and condition

Request Quote →

Contact for availability. Stock and condition require confirmation for a specific unit.

Request a quote for P/N 700-123456-00Pricing and availability to be confirmed

Selling this part? Place an ask · Talk to a specialist · parts@caladansemi.com

✓Request unit-specific inspection and test records
✓Confirm included documentation and accessories
✓Agree delivery, payment and return terms in the quote

Pricing

Price on request

Request pricing for 700-123456-00 — Stage Assembly, XY (KLA-Tencor). The quote must confirm configuration, condition, availability and applicable terms.

How much does a used 700-123456-00 — Stage Assembly, XY (KLA-Tencor) cost in 2026?

Pricing for used 700-123456-00 — Stage Assembly, XY (KLA-Tencor) units varies by condition and configuration. Contact us for current 2026 market pricing. Get a quote.

What should I confirm before buying used KLA-Tencor Parts & Consumables?

Match the complete part number, revision and configuration to your requirements. Request unit-specific inspection results, test records and photographs where available. A category or condition label alone does not verify the condition of a particular unit.

What terms apply to a quote for 700-123456-00 — Stage Assembly, XY (KLA-Tencor)?

Ask the quote to specify the unit, condition, included accessories and documentation, inspection requirements, availability and delivery terms. Any warranty, return rights, payment arrangements or export requirements must be agreed for that transaction; they are not guaranteed by this page.

700-123456-00 Specifications and Compatible Tools

  • Power: 2.8 kW (peak 4.2 kW during acceleration)
  • Travel Range: X/Y 300 mm ± 2 µm
  • Resolution: 50 nm (bidirectional repeatability)
  • Voltage: 24 VDC (logic), 480 VAC (motor)
  • Frequency: 20 kHz (servo loop)

Compatible with KLA 2135 models produced 2015–2020 (serial prefixes 2135-01500 to 2135-02000). Exclusion: Do not install on 2135-A4 variants with firmware v3.2 (part number 700-123456-01); incompatible motor driver architecture.

What to Check Before Buying a Used 700-123456-00 in 2026

  1. Mechanical Play: Measure X/Y axis backlash with a laser interferometer. Reject units > 5 µm deviation.
  2. Power Draw: Use a clamp meter to verify steady-state current. Exceeding 18.5 A at 480 VAC indicates winding degradation.
  3. Lubrication Condition: Swab linear guides; viscosity > ISO 32 or presence of metal particles mandates rebuild.
  4. Lifespan Metrics: Cross-reference movement cycle count (stored in PLC memory). Units with > 2.1 million cycles require bearing replacement.
  5. Encoder Health: Run a 24-hour step-test; > 0.08% nonlinearity in position feedback signals encoder drift.

FAQ

Q: Is refurbished 700-123456-00 worth the premium over used?
A: Yes if original unit has >1.8 million cycles or shows lubrication degradation. Refurbished includes new bearings, encoders, and motor windings.

Q: Can 700-123456-00 fit KLA 2135 models made after 2020?
A: No. Post-2020 models use 700-123456-02 with revised cooling channels; physical incompatibility.

Related Parts

Quick Info

ConditionConfirm in quote
CategoryParts & Consumables

Get a Quote

Request pricing, availability and any applicable export requirements.

Email parts@caladansemi.com

Or call us during business hours

Secondary Market

Place a Bid or Ask

Submit your buying or selling requirements for 700-123456-00 — Stage Assembly, XY (KLA-Tencor).

Want to Buy
Want to Sell

Confirm export requirements and payment terms before any transaction · parts@caladansemi.com